Experimental study on the thermal performance of a closed loop pulsating heat pipe with various position.
Rana, Mohammad Masud; Pranto, Md. Wahiduzzaman; Rahman, Md. Jihan; Bepari, Md. Rumman; Khatun, Sharifa
Abstract
Research on closed loop pulsating heat pipes (CLPHPs) using Methanol and Ethylene Glycol as working fluids elucidates key design considerations for maximizing thermal performance. Both studies concur that a 50% filling ratio optimally balances vapor and liquid phases to facilitate effective pulsating flows. However, optimal inclination angles varied; Methanol achieved peak performance at 45°, while Ethylene Glycol was most effective at 35°. Regardless of the working fluid, vertical orientations at 90° yielded the poorest performance due to flow stratification effects. The findings indicate that an angled orientation between 35-45° significantly improves thermal efficiency, though the exact optimal angle may be fluid-specific and warrants further investigation